After running continuously for several days, the ammeter starts sending back empty packets.
Assignee | ||
Updated•10 years ago
|
Assignee: nobody → jhylands
Status: NEW → ASSIGNED
Keywords: perf
OS: Windows 7 → Linux
Priority: -- → P1
Whiteboard: [c=power p=2 s= u=]
Assignee | ||
Comment 1•10 years ago
|
||
I added some debug code to the ammeter to help pin-point the problem, and it appears to have solved it, which suggests this was strictly a timing-based issue. I'll close this now, and re-open if it happens again. https://github.com/JonHylands/MozAvrAmmeter/commit/d79475905cbeed1bda27c73e842fcff277019ff0 Ammeter version upped to 0.6 with this commit.
Status: ASSIGNED → RESOLVED
Closed: 10 years ago
Resolution: --- → FIXED
Assignee | ||
Comment 2•10 years ago
|
||
So, it turns out it took almost 2 weeks to show up this time. I've added some more debug info, hopefully will allow me to diagnose this.
Status: RESOLVED → REOPENED
Resolution: FIXED → ---
Comment 3•6 years ago
|
||
This project isn't maintained anymore.
Status: REOPENED → RESOLVED
Closed: 10 years ago → 6 years ago
Resolution: --- → WONTFIX