Closed
Bug 1117685
Opened 9 years ago
Closed 9 years ago
HP Log on node26.peach.metrics.scl3.mozilla.com is CRITICAL: CRITICAL 0008: Drive Array Controller Failure (Slot 0)
Categories
(Infrastructure & Operations :: MOC: Problems, task)
Tracking
(Not tracked)
RESOLVED
FIXED
People
(Reporter: nagiosapi, Unassigned)
References
()
Details
(Whiteboard: [id=nagios1.private.scl3.mozilla.com:506576])
Automated alert report from nagios1.private.scl3.mozilla.com: Hostname: node26.peach.metrics.scl3.mozilla.com Service: HP Log State: CRITICAL Output: CRITICAL 0008: Drive Array Controller Failure (Slot 0) Runbook: http://m.allizom.org/HP+Log
Comment 1•9 years ago
|
||
It looks good from here. [root@node26.peach.metrics.scl3 ~]# hpasmcli HP management CLI for Linux (v2.0) Copyright 2008 Hewlett-Packard Development Group, L.P. -------------------------------------------------------------------------- NOTE: Some hpasmcli commands may not be supported on all Proliant servers. Type 'help' to get a list of all top level commands. -------------------------------------------------------------------------- hpasmcli> quit [root@node26.peach.metrics.scl3 ~]# hpacucli ctrl slot=0 pd all show Smart Array P420i in Slot 0 (Embedded) array A physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 3 TB, OK) array B physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 3 TB, OK) array C physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 3 TB, OK) array D physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 3 TB, OK) array E physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SATA, 3 TB, OK) array F physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SATA, 3 TB, OK) array G physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SATA, 3 TB, OK) array H physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SATA, 3 TB, OK) array I physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SATA, 3 TB, OK) array J physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SATA, 3 TB, OK) array K physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SATA, 3 TB, OK) array L physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SATA, 3 TB, OK) [root@node26.peach.metrics.scl3 ~]#
Comment 2•9 years ago
|
||
root@node26.peach.metrics.scl3 ~]# hplog -v ID Severity Initial Time Update Time Count ------------------------------------------------------------- 0003 Information 00:01 08/14/2012 00:01 08/14/2012 0001 LOG: POST Information: Processor 1, DIMM 1 could not be authenticated as genuine HP SmartMemory. Enhanced and extended HP SmartMemory features will not be active. 0004 Information 16:17 07/16/2014 16:17 07/16/2014 0001 LOG: Maintenance note: Updated Power Management Controller firmware to version 3.3 0005 Information 16:50 07/16/2014 16:50 07/16/2014 0001 LOG: Firmware flashed (ProLiant System BIOS - A28 06/09/2013) 0006 Information 00:46 07/17/2014 00:46 07/17/2014 0001 LOG: Firmware flashed (iLO 4 1.51) 0007 Information 16:50 10/13/2014 16:50 10/13/2014 0001 LOG: Firmware flashed (iLO 4 2.02) 0008 Critical 08:16 01/05/2015 08:16 01/05/2015 0001 LOG: Drive Array Controller Failure (Slot 0) [root@node26.peach.metrics.scl3 ~]#
Reporter | ||
Comment 3•9 years ago
|
||
Automated alert recovery: Hostname: node26.peach.metrics.scl3.mozilla.com Service: HP Log State: OK Output: OK 0000: Maintenance note: IML cleared through hpasmcli
Status: NEW → RESOLVED
Closed: 9 years ago
Resolution: --- → FIXED
Assignee | ||
Updated•8 years ago
|
Component: MOC: Incidents → MOC: Problems