Hardware Error Northbridge Error (node 2): DRAM ECC error detected on the NB web10.mktweb.services.phx1.mozilla.com
Categories
(Cloud Services :: Operations: Marketplace, task)
Cloud Services
Operations: Marketplace
Tracking
(Not tracked)
RESOLVED
FIXED
People
(Reporter: jason, Assigned: jlaz)
Details
(Whiteboard: [HP Case: 4649442307, 4649442360])
[Hardware Error]: CPU:1 MC4_STATUS[-|CE|MiscV|-|AddrV|-|-|CECC]: 0x8c40400020080813
[Hardware Error]: MC4_ADDR: 0x0000001542627e60
[Hardware Error]: Northbridge Error (node 2): DRAM ECC error detected on the NB.
EDAC amd64 MC2: CE ERROR_ADDRESS= 0x1542627e60
EDAC MC2: CE page 0x1542627, offset 0xe60, grain 0, syndrome 0x2080, row 2, channel 0, label "": amd64_edac
[Hardware Error]: cache level: L3/GEN, mem/io: MEM, mem-tx: RD, part-proc: SRC (no timeout)
[Hardware Error]: CPU:1 MC4_STATUS[-|CE|MiscV|-|AddrV|-|-|CECC]: 0x8c40400020080813
[Hardware Error]: MC4_ADDR: 0x0000001542627e60
[Hardware Error]: Northbridge Error (node 2): DRAM ECC error detected on the NB.
EDAC amd64 MC2: CE ERROR_ADDRESS= 0x1542627e60
EDAC MC2: CE page 0x1542627, offset 0xe60, grain 0, syndrome 0x2080, row 2, channel 0, label "": amd64_edac
[Hardware Error]: cache level: L3/GEN, mem/io: MEM, mem-tx: RD, part-proc: SRC (no timeout)
Assignee | ||
Comment 1•10 years ago
|
||
HP Case: 4649442307 for failed RAID controller
HP Case: 4649442360 for DRAM issue
Whiteboard: [HP Case: 4649442307, 4649442360]
Reporter | ||
Updated•10 years ago
|
Assignee: nobody → jlaz
Assignee | ||
Comment 2•10 years ago
|
||
Hardware serviced, back in prod