Closed Bug 1112477 Opened 11 years ago Closed 11 years ago

HP RAID on graphite6.private.phx1.mozilla.com is CRITICAL: RAID CRITICAL - HP Smart Array Failed: Smart Array P220i in Slot 0 (Embedded) array A logicaldrive 1 (279.4 GB, RAID 1, OK) Smart Array P410i in Slot 3 array A logicaldrive 1 (4.9 TB, RAID 1+0, I

Categories

(Infrastructure & Operations :: DCOps, task)

Other
Other
task
Not set
normal

Tracking

(Not tracked)

RESOLVED FIXED

People

(Reporter: dgarvey, Unassigned)

References

()

Details

(Whiteboard: [id=nagios1.private.phx1.mozilla.com:413647] CaseID:4650218584)

+++ This bug was initially created as a clone of Bug #1112475 +++ Automated alert report from nagios1.private.phx1.mozilla.com: Hostname: graphite6.private.phx1.mozilla.com Service: HP RAID State: CRITICAL Output: RAID CRITICAL - HP Smart Array Failed: Smart Array P220i in Slot 0 (Embedded) array A logicaldrive 1 (279.4 GB, RAID 1, OK) Smart Array P410i in Slot 3 array A logicaldrive 1 (4.9 TB, RAID 1+0, Interim Recovery Mode) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 900.1 GB, Failed) Runbook: http://m.allizom.org/HP+RAID
[root@graphite6.private.phx1 ~]# hpacucli ctrl all show config Smart Array P220i in Slot 0 (Embedded) (sn: PCQVU0CRH5H273) logicaldrive 1 (279.4 GB, RAID 1, OK) array A (SAS, Unused Space: 0 MB) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK) SEP (Vendor ID PMCSIERA, Model SRCv4x6G) 380 (WWID: 50014380284EE98F) Smart Array P410i in Slot 3 (sn: 50014380259052A0) logicaldrive 1 (4.9 TB, RAID 1+0, Interim Recovery Mode) array A (SAS, Unused Space: 0 MB) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 900.1 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 900.1 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 900.1 GB, Failed) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 900.1 GB, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 900.1 GB, OK) physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 900.1 GB, OK) physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 900.1 GB, OK) physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 900.1 GB, OK) physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SAS, 900.1 GB, OK) physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SAS, 900.1 GB, OK) physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SAS, 900.1 GB, OK) physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SAS, 900.1 GB, OK) Expander 250 (WWID: 50014380251EE766, Port: 1I, Box: 1) Enclosure SEP (Vendor ID HP, Model D2200sbx12) 248 (WWID: 50014380251EE765, Port: 1I, Box: 1) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 249 (WWID: 50014380259052AF) [root@graphite6.private.phx1 ~]#
colo-trip: --- → scl3
colo-trip: scl3 → phx1
CaseID:4650218584 opened for HP tech to come out and swap 900GB SAS drive on storage blade.
Whiteboard: [id=nagios1.private.phx1.mozilla.com:413647] → [id=nagios1.private.phx1.mozilla.com:413647] CaseID:4650218584
rebuild complete. [vle@graphite6.private.phx1 ~]$ sudo hpacucli ctrl all show config Smart Array P220i in Slot 0 (Embedded) (sn: PCQVU0CRH5H273) logicaldrive 1 (279.4 GB, RAID 1, OK) array A (SAS, Unused Space: 0 MB) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK) SEP (Vendor ID PMCSIERA, Model SRCv4x6G) 380 (WWID: 50014380284EE98F) Smart Array P410i in Slot 3 (sn: 50014380259052A0) logicaldrive 1 (4.9 TB, RAID 1+0, OK) array A (SAS, Unused Space: 0 MB) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 900.1 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 900.1 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 900.1 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 900.1 GB, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 900.1 GB, OK) physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 900.1 GB, OK) physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 900.1 GB, OK) physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 900.1 GB, OK) physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SAS, 900.1 GB, OK) physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SAS, 900.1 GB, OK) physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SAS, 900.1 GB, OK) physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SAS, 900.1 GB, OK) Expander 250 (WWID: 50014380251EE766, Port: 1I, Box: 1) Enclosure SEP (Vendor ID HP, Model D2200sbx12) 248 (WWID: 50014380251EE765, Port: 1I, Box: 1) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 249 (WWID: 50014380259052AF)
Status: NEW → RESOLVED
Closed: 11 years ago
Resolution: --- → FIXED