backup2.db.phx1.mozilla.com:HP RAID is WARNING
Categories
(Infrastructure & Operations :: DCOps, task)
Tracking
(Not tracked)
RESOLVED
FIXED
People
(Reporter: dgarvey, Unassigned)
References
Details
Logical Drive: 1
Size: 3.3 TB
Fault Tolerance: RAID 1+0
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 256 KB
Full Stripe Size: 1536 KB
Status: OK
Caching: Enabled
Unique Identifier: 600508B1001CFFE884CCF2E13A97A463
Disk Name: /dev/sda
Mount Points: None
Logical Drive Label: AEED0679500143801644EC28A3DF
Mirror Group 0:
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, OK)
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 600 GB, OK)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 600 GB, OK)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 600 GB, OK)
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 600 GB, OK)
Mirror Group 1:
physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 600 GB, OK)
physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 600 GB, OK)
physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SAS, 600 GB, Predictive Failure)
physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SAS, 600 GB, OK)
physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SAS, 600 GB, OK)
physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SAS, 600 GB, OK)
physicaldrive 1I:1:9
Port: 1I
Box: 1
Bay: 9
Status: Predictive Failure
Drive Type: Data Drive
Interface Type: SAS
Size: 600 GB
Rotational Speed: 10000
Firmware Revision: HPD7
Serial Number: 6XR16Q880000B147HGJ0
Model: HP EG0600FBLSH
Current Temperature (C): 35
Maximum Temperature (C): 48
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
| Reporter | ||
Updated•10 years ago
|
Assignee: nobody → server-ops-dcops
Component: MOC: Problems → DCOps
QA Contact: lypulong
Updated•10 years ago
|
colo-trip: --- → phx1
Comment 2•10 years ago
|
||
host is out of warranty. found a spare 600GB SAS drive from one of the decommissioned blades.
Serial Number: MXQ1440XGM
Product number: 603251-B21
Warranty Status: Expired
Contract Status: Expired
swapped drive and host is rebuilding.
[vle@backup2.db.phx1 ~]$ sudo hpacucli controller slot=3 pd all show
Smart Array P410i in Slot 3
array A
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, OK)
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 600 GB, OK)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 600 GB, OK)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 600 GB, OK)
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 600 GB, OK)
physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 600 GB, OK)
physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 600 GB, OK)
physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SAS, 600 GB, Rebuilding)
physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SAS, 600 GB, OK)
physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SAS, 600 GB, OK)
physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SAS, 600 GB, OK)
Comment 3•10 years ago
|
||
looks like spare drive i found worked.
13:57 < nagios-phx1> Wed 13:57:07 PDT [1077] backup2.db.phx1.mozilla.com:HP RAID is OK: RAID OK: Smart Array P410i in Slot 0 (Embedded) array A
logicaldrive 1 (279.4 GB, RAID 1, OK) Smart Array P410i in Slot 3 array A logicaldrive 1 (3.3 TB, RAID 1+0, OK) [Controller Status:
OK Cache Status: OK Battery/Capacitor Status: OK Controller Status: OK Cache Status: OK Battery/Capacitor Status: OK]
(http://m.mozilla.org/HP+RAID)
Status: NEW → RESOLVED
Closed: 10 years ago
Resolution: --- → FIXED