backup2.db.phx1.mozilla.com:HP RAID is WARNING

Categories

(Infrastructure & Operations :: DCOps, task)

x86_64
Linux
task
Not set
normal

Tracking

(Not tracked)

RESOLVED FIXED

People

(Reporter: dgarvey, Unassigned)

References

Details

Logical Drive: 1 Size: 3.3 TB Fault Tolerance: RAID 1+0 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 256 KB Full Stripe Size: 1536 KB Status: OK Caching: Enabled Unique Identifier: 600508B1001CFFE884CCF2E13A97A463 Disk Name: /dev/sda Mount Points: None Logical Drive Label: AEED0679500143801644EC28A3DF Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 600 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 600 GB, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 600 GB, OK) physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 600 GB, OK) Mirror Group 1: physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 600 GB, OK) physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 600 GB, OK) physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SAS, 600 GB, Predictive Failure) physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SAS, 600 GB, OK) physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SAS, 600 GB, OK) physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SAS, 600 GB, OK) physicaldrive 1I:1:9 Port: 1I Box: 1 Bay: 9 Status: Predictive Failure Drive Type: Data Drive Interface Type: SAS Size: 600 GB Rotational Speed: 10000 Firmware Revision: HPD7 Serial Number: 6XR16Q880000B147HGJ0 Model: HP EG0600FBLSH Current Temperature (C): 35 Maximum Temperature (C): 48 PHY Count: 2 PHY Transfer Rate: 6.0Gbps, Unknown
Assignee: nobody → server-ops-dcops
Component: MOC: Problems → DCOps
QA Contact: lypulong
colo-trip: --- → phx1
host is out of warranty. found a spare 600GB SAS drive from one of the decommissioned blades. Serial Number: MXQ1440XGM Product number: 603251-B21 Warranty Status: Expired Contract Status: Expired swapped drive and host is rebuilding. [vle@backup2.db.phx1 ~]$ sudo hpacucli controller slot=3 pd all show Smart Array P410i in Slot 3 array A physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 600 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 600 GB, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 600 GB, OK) physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 600 GB, OK) physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 600 GB, OK) physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 600 GB, OK) physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SAS, 600 GB, Rebuilding) physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SAS, 600 GB, OK) physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SAS, 600 GB, OK) physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SAS, 600 GB, OK)
looks like spare drive i found worked. 13:57 < nagios-phx1> Wed 13:57:07 PDT [1077] backup2.db.phx1.mozilla.com:HP RAID is OK: RAID OK: Smart Array P410i in Slot 0 (Embedded) array A logicaldrive 1 (279.4 GB, RAID 1, OK) Smart Array P410i in Slot 3 array A logicaldrive 1 (3.3 TB, RAID 1+0, OK) [Controller Status: OK Cache Status: OK Battery/Capacitor Status: OK Controller Status: OK Cache Status: OK Battery/Capacitor Status: OK] (http://m.mozilla.org/HP+RAID)