Closed Bug 1215827 Opened 10 years ago Closed 10 years ago

replace failing disk on hgweb10

Categories

(Infrastructure & Operations :: DCOps, task)

task
Not set
normal

Tracking

(Not tracked)

RESOLVED FIXED

People

(Reporter: Usul, Assigned: van)

Details

(Whiteboard: OOW 2/6/2015)

[lhirlimann@hgweb10.dmz.scl3 ~]$ sudo hpacucli controller slot=0 show config Smart Array P410i in Slot 0 (Embedded) (sn: 5001438018BEEC20) Internal Drive Cage at Port 1I, Box 1, OK array A (SAS, Unused Space: 0 MB) logicaldrive 1 (1.6 TB, RAID 1+0, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 900.1 GB, Predictive Failure) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 900.1 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 900.1 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 900.1 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 5001438018BEEC2F) [lhirlimann@hgweb10.dmz.scl3 ~]$
If we need to bring the host down, please coordinate with :gps, :hwine, or me so that we can remove from zeus and resync mirrors once it's up.
this host is OOW since 2/6/2015, please let me know if we need to renew.
Flags: needinfo?(klibby)
Whiteboard: OOW 2/6/2015
found a spare, host rebuilding. [vle@hgweb10.dmz.scl3 ~]$ sudo -i hpacucli ctrl all show config Smart Array P410i in Slot 0 (Embedded) (sn: 5001438018BEEC20) Internal Drive Cage at Port 1I, Box 1, OK array A (SAS, Unused Space: 0 MB) logicaldrive 1 (1.6 TB, RAID 1+0, Recovering, 1% complete) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 900.1 GB, Rebuilding) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 900.1 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 900.1 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 900.1 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 5001438018BEEC2F)
Assignee: server-ops-dcops → vle
QA Contact: jbarnell
rebuild complete. going to close bug as issue is resolved but leaving need-info for you to review. please let me know if you want to renew warranty on this host. [vle@hgweb10.dmz.scl3 ~]$ sudo -i hpacucli ctrl all show config Smart Array P410i in Slot 0 (Embedded) (sn: 5001438018BEEC20) Internal Drive Cage at Port 1I, Box 1, OK array A (SAS, Unused Space: 0 MB) logicaldrive 1 (1.6 TB, RAID 1+0, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 900.1 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 900.1 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 900.1 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 900.1 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 5001438018BEEC2F)
Status: NEW → RESOLVED
Closed: 10 years ago
Resolution: --- → FIXED
Uncertain on warranty renewal, turns out we have a bunch of out of warranty machines. Will open new bug for 'em. Thanks!
Flags: needinfo?(klibby)