Hi team, Internal Disk is failing We would need your assistance to replace the failing disk. I have already removed the server and disk from operations on CDH and is ready for replacement. Information for the disk below: [root@node23.peach.metrics.scl3 ~]# hpacucli controller slot=0 physicaldrive all show Smart Array P420i in Slot 0 (Embedded) array A physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 3 TB, OK) array B physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 3 TB, Predictive Failure) array C physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 3 TB, OK) array D physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 3 TB, OK) array E physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SATA, 3 TB, OK) array F physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SATA, 3 TB, OK) array G physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SATA, 3 TB, OK) array H physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SATA, 3 TB, OK) array I physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SATA, 3 TB, OK) array J physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SATA, 3 TB, OK) array K physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SATA, 3 TB, OK) array L physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SATA, 3 TB, OK) [root@node23.peach.metrics.scl3 ~]# [root@node23.peach.metrics.scl3 ~]# hpacucli controller slot=0 array B show Smart Array P420i in Slot 0 (Embedded) Array: B Interface Type: SATA Unused Space: 0 MB Status: OK Array Type: Data HP SSD Smart Path: disable [root@node23.peach.metrics.scl3 ~]# hpacucli controller slot=0 logicaldrive 2 show Smart Array P420i in Slot 0 (Embedded) array B Logical Drive: 2 Size: 2.7 TB Fault Tolerance: 0 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 256 KB Full Stripe Size: 256 KB Status: OK Caching: Enabled Unique Identifier: 600508B1001CEE2A8FB365850D9949EC Disk Name: /dev/sdb Mount Points: /data2 2.7 TB Partition Number 5 OS Status: LOCKED Logical Drive Label: A20D83535001438025189BC0 6F38 Drive Type: Data LD Acceleration Method: Controller Cache [root@node23.peach.metrics.scl3 ~]# hpacucli controller slot=0 physicaldrive 1I:1:2 show Smart Array P420i in Slot 0 (Embedded) array B physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 Status: Predictive Failure Drive Type: Data Drive Interface Type: SATA Size: 3 TB Native Block Size: 512 Rotational Speed: 7200 Firmware Revision: HPG1 Serial Number: WCC130023915 Model: ATA MB3000GCVBT SATA NCQ Capable: True SATA NCQ Enabled: True Current Temperature (C): 35 Maximum Temperature (C): 45 PHY Count: 1 PHY Transfer Rate: 6.0Gbps Drive Authentication Status: OK Carrier Application Version: 11 Carrier Bootloader Version: 6 Regards, Nicolas Parducci Pythian SRE team
Status: NEW → RESOLVED
Closed: 9 years ago
Resolution: --- → DUPLICATE
You need to log in before you can comment on or make changes to this bug.