Closed
Bug 1263246
Opened 9 years ago
Closed 9 years ago
Disk failing on node23.peach.metrics.scl3.mozilla.com
Categories
(Infrastructure & Operations :: DCOps, task)
Tracking
(Not tracked)
RESOLVED
DUPLICATE
of bug 1262667
People
(Reporter: u550631, Unassigned)
Details
Hi team,
Internal Disk is failing We would need your assistance to replace the failing disk.
I have already removed the server and disk from operations on CDH and is ready for replacement.
Information for the disk below:
[root@node23.peach.metrics.scl3 ~]# hpacucli controller slot=0 physicaldrive all show
Smart Array P420i in Slot 0 (Embedded)
array A
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 3 TB, OK)
array B
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 3 TB, Predictive Failure)
array C
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 3 TB, OK)
array D
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 3 TB, OK)
array E
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SATA, 3 TB, OK)
array F
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SATA, 3 TB, OK)
array G
physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SATA, 3 TB, OK)
array H
physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SATA, 3 TB, OK)
array I
physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SATA, 3 TB, OK)
array J
physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SATA, 3 TB, OK)
array K
physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SATA, 3 TB, OK)
array L
physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SATA, 3 TB, OK)
[root@node23.peach.metrics.scl3 ~]#
[root@node23.peach.metrics.scl3 ~]# hpacucli controller slot=0 array B show
Smart Array P420i in Slot 0 (Embedded)
Array: B
Interface Type: SATA
Unused Space: 0 MB
Status: OK
Array Type: Data
HP SSD Smart Path: disable
[root@node23.peach.metrics.scl3 ~]# hpacucli controller slot=0 logicaldrive 2 show
Smart Array P420i in Slot 0 (Embedded)
array B
Logical Drive: 2
Size: 2.7 TB
Fault Tolerance: 0
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 256 KB
Full Stripe Size: 256 KB
Status: OK
Caching: Enabled
Unique Identifier: 600508B1001CEE2A8FB365850D9949EC
Disk Name: /dev/sdb Mount Points: /data2 2.7 TB Partition Number 5
OS Status: LOCKED
Logical Drive Label: A20D83535001438025189BC0 6F38
Drive Type: Data
LD Acceleration Method: Controller Cache
[root@node23.peach.metrics.scl3 ~]# hpacucli controller slot=0 physicaldrive 1I:1:2 show
Smart Array P420i in Slot 0 (Embedded)
array B
physicaldrive 1I:1:2
Port: 1I
Box: 1
Bay: 2
Status: Predictive Failure
Drive Type: Data Drive
Interface Type: SATA
Size: 3 TB
Native Block Size: 512
Rotational Speed: 7200
Firmware Revision: HPG1
Serial Number: WCC130023915
Model: ATA MB3000GCVBT
SATA NCQ Capable: True
SATA NCQ Enabled: True
Current Temperature (C): 35
Maximum Temperature (C): 45
PHY Count: 1
PHY Transfer Rate: 6.0Gbps
Drive Authentication Status: OK
Carrier Application Version: 11
Carrier Bootloader Version: 6
Regards,
Nicolas Parducci
Pythian SRE team
Updated•9 years ago
|
Status: NEW → RESOLVED
Closed: 9 years ago
Resolution: --- → DUPLICATE
You need to log in
before you can comment on or make changes to this bug.