Closed Bug 1571942 Opened 5 years ago Closed 5 years ago

Pick element keyboard shortcut focuses the devtools window if the inspector tool was not selected

Categories

(DevTools :: Inspector, defect, P2)

defect

Tracking

(firefox71 fixed)

RESOLVED FIXED
Firefox 71
Tracking Status
firefox71 --- fixed

People

(Reporter: daisuke, Assigned: daisuke)

References

(Blocks 2 open bugs)

Details

(Whiteboard: [dt-q])

Attachments

(2 files)

This is a follow up for a report from Julian in bug 149187:

https://phabricator.services.mozilla.com/D40378#inline-247342

Note that this is only called when the inspector is already the selected tool.
For the STRs:

open devtools in window host
select webconsole
focus content page
trigger inspector shortcut

, the devtools window will still be focused.

I also could reproduce it. However, I'm not sure this behavior is bad or not. So, we need to decide the behavior first, then let's fix this if needed.

This was fixed recently if you are in the inspector, but it's still a problem if you are in another tool as the STR say.
So let's fix this. Moving this to be a defect.

Type: enhancement → defect
Priority: -- → P2
Whiteboard: [dt-q]

I'm sorry, the bug number which I reported was wrong.
The correct is bug 1491874.

Blocks: 1579314
Blocks: 1579321
Pushed by dakatsuka.birchill@mozilla.com:
https://hg.mozilla.org/integration/autoland/rev/7babba8a17f6
Avoid to raise the toolbox whenever the shortcut key of inspector was typed. r=jdescottes
https://hg.mozilla.org/integration/autoland/rev/1970fc59ee5f
Add a test for inspector shortcut in case that other tool is selected. r=jdescottes
Status: NEW → RESOLVED
Closed: 5 years ago
Resolution: --- → FIXED
Target Milestone: --- → Firefox 71
Assignee: nobody → daisuke
You need to log in before you can comment on or make changes to this bug.