Details |
It's not easy right now to witness Windows version changes in the WDBA data. We can see population-wide changes but we can't correlate version changes with browser default changes. Including previous Windows version information in WDBA pings would address this.
Updated•3 years ago
|
Updated•3 years ago
|
Updated•3 years ago
|
Comment 1•3 years ago
|
||
HKLM:\Software\Microsoft\Windows NT\CurrentVersion' 'UBR'?
Updated•3 years ago
|
| Assignee | ||
Comment 2•3 years ago
|
||
(In reply to Max from comment #1)
HKLM:\Software\Microsoft\Windows NT\CurrentVersion' 'UBR'?
The UBR is currently included in the os_version, so nothing more is needed here.
I have a version of this implemented locally; I'm working on some tests for it as we speak. I'll take this and either submit it or pass it to another engineer if I get called away.
| Assignee | ||
Comment 3•2 years ago
|
||
This adds both the current os_version and the previous_os_version
to both legacy and Glean pings. This appears to duplice the built-in
Glean os_version metric, but they are not the same format as the
legacy telemetry: Glean records the UBR as a separate metric.
Depends on D196119
| Assignee | ||
Comment 4•2 years ago
|
||
Comment 5•2 years ago
|
||
Comment on attachment 9368074 [details]
bug1850149.md
Data Review
- Is there or will there be documentation that describes the schema for the ultimate data set in a public, complete, and accurate way?
Yes, through the metrics.yaml file and the Glean Dictionary.
- Is there a control mechanism that allows the user to turn the data collection on and off?
Yes, through the data preferences in the application settings.
- If the request is for permanent data collection, is there someone who will monitor the data over time?
Permanent collection to be monitored over time by nalexander and install-update@mozilla.com
- Using the category system of data types on the Mozilla wiki, what collection type of data do the requested measurements fall under?
Category 1, Technical data
- Is the data collection request for default-on or default-off?
Default-on
- Does the instrumentation include the addition of any new identifiers (whether anonymous or otherwise; e.g., username, random IDs, etc. See the appendix for more details)?
No
- Is the data collection covered by the existing Firefox privacy notice?
Yes
- Does the data collection use a third-party collection tool?
No
Result
data-review+
Comment 7•2 years ago
|
||
| bugherder | ||
| Assignee | ||
Comment 8•2 years ago
|
||
Completing a loop here: https://sql.telemetry.mozilla.org/queries/96588/source?p_channel=nightly&p_date=d_last_7_day shows a few thousand Nightly Glean pings that have system_os_previous_version non-NULL.
| Assignee | ||
Comment 9•2 years ago
|
||
This commit uses toolkit.telemetry.service to configure the
telemetry ingestion endpoing, and respects
datareporting.healthreport.uploadEnabled. The latter should be
enabled for all WDBA profiles in the wild.
Both support testing the underlying functionality.