Closed Bug 294081 Opened 20 years ago Closed 19 years ago

zombie alarm text back from the dead!

Categories

(Calendar :: Internal Components, defect)

Sunbird 0.2
x86
Linux
defect
Not set
normal

Tracking

(Not tracked)

VERIFIED WORKSFORME

People

(Reporter: jwz, Unassigned)

Details

Months ago, I set an alarm to go off today.  It had title and body "X".

Yesterday, I changed the title and body of that alarm to be "Y".
(I have not quit Sunbird since then.)

Today, the alarm went off, and the alarm dialog shows text "X".

When I click the "Edit" button on that dialog, it shows me text "X".

My actual calendar window shows text "Y".  When I double-click on it, it still
shows me text "Y".

So somehow the alarm mechanism is holding on to an undead event object that is
not actually present in the calendar any more!
Unfortunately, I do not have cycles to work on Calendar stuff these days (just as it's getting to the good part!), so I am a bad owner for these bugs.  To delete the tragically-large chunk of bugspam, search for gregorianabdication.
Assignee: shaver → nobody
We drop alarms at every restart, and also clear them out when events are deleted now.  Marking WFM.
Status: NEW → RESOLVED
Closed: 19 years ago
Resolution: --- → WORKSFORME
Status: RESOLVED → VERIFIED
Version: Sunbird 0.2RC2 → Sunbird 0.2