Closed Bug 324829 Opened 20 years ago Closed 19 years ago

toolkit windows installer is brittle on line endings during build

Categories

(Toolkit Graveyard :: Build Config, defect)

x86
Windows XP
defect
Not set
normal

Tracking

(Not tracked)

RESOLVED FIXED

People

(Reporter: Pike, Unassigned)

Details

Attachments

(1 obsolete file)

If toolkit/installer/windows/install.it doesn't have a trailing newline, the build creates a install.ini in the build that looks somewhat like this: ERROR_PATH_WITHIN_WINDIR=Programa negali b<FB>ti <E1>diegta <E1> <84>Windows<93> katalogo pakatalog<E1>. Pra<F0>om parinkti kit<E0> katalog<E0>.AB_CD=lt I.e., it doesn't have the define for AB_CD or some other entity, which completely confuses the installer. And leads to crashes. This happened both for cz 1.5 rc1 and lt 1.5.0.1 candidate.
Attached patch Patch for lt install.it (obsolete) — — Splinter Review
Attaching a patch for lt toolkit/installer/windows/installer.it with new lines at the end of file added. Could I commit it to 1_8_0, 1_8 branches?
Comment on attachment 209815 [details] [diff] [review] Patch for lt install.it I already did ;-)
Attachment #209815 - Attachment is obsolete: true
install.it is not cvs removed yet, but dead anyway. Closing.
Status: NEW → RESOLVED
Closed: 19 years ago
Resolution: --- → FIXED
Product: Toolkit → Toolkit Graveyard
You need to log in before you can comment on or make changes to this bug.