Closed Bug 554962 Opened 16 years ago Closed 16 years ago

Removing toolbars with glass creates rendering artifacts in content

Categories

(Core :: Widget: Win32, defect)

x86
Windows Vista
defect
Not set
normal

Tracking

()

RESOLVED DUPLICATE of bug 554959

People

(Reporter: johnath, Unassigned)

Details

(Keywords: regression)

Attachments

(1 file)

STR 1) Use a windows build with glass enabled 2) Customize the browser to remove toolbars/menus 3) Notice that the top few lines of content, corresponding to the area formerly covered with UI, is persistently broken. See attachment
This is because the edge of the inner frame (denoting the opaque region) is moving.
Status: NEW → RESOLVED
Closed: 16 years ago
Resolution: --- → DUPLICATE
You need to log in before you can comment on or make changes to this bug.