What should happen, even with leaks, is that we run the CC twice at shutdown: once to free everything, then another time to confirm that there's nothing to free. This wasn't actually always true, due to some weirdness that I fixed. Anyways, warning for this will help figure out which shutdown CC we should log, in leaks like bug 858948. If I'm feeling a little more brave, I'll make this an assertion.
Assignee | ||
Comment 1•11 years ago
|
||
Let's see if it fails as an assertion. https://tbpl.mozilla.org/?tree=Try&rev=847064a62b8f
Assignee | ||
Comment 2•11 years ago
|
||
Attachment #751891 -
Attachment is obsolete: true
Attachment #753896 -
Flags: review?(bugs)
Updated•11 years ago
|
Attachment #753896 -
Flags: review?(bugs) → review+
Assignee | ||
Comment 3•11 years ago
|
||
https://hg.mozilla.org/integration/mozilla-inbound/rev/6d43a8c88ddc
Comment 4•11 years ago
|
||
https://hg.mozilla.org/mozilla-central/rev/6d43a8c88ddc
Status: NEW → RESOLVED
Closed: 11 years ago
Resolution: --- → FIXED
Target Milestone: --- → mozilla24