Closed Bug 1149599 Opened 10 years ago Closed 10 years ago

Telemetry should do a subsession split when the computer wakes up from sleep

Categories

(Toolkit :: Telemetry, defect)

defect
Not set
normal

Tracking

()

RESOLVED WORKSFORME
Tracking Status
firefox40 --- affected

People

(Reporter: gfritzsche, Unassigned)

References

Details

When the computer wakes up from sleep we may have slept past midnight etc. We should do a subsession split right at wakeup to avoid e.g. the following scenario: * computer goes to sleep on monday 23:00 * computer wakes up on wednesday 2pm * we wait for the next scheduler tick * we notice that the daily ping is overdue and collect & submit => now we end up with a little bit of wednesday data after wakeup in the "daily" ping that should represent monday
Per todays meeting Alessio and Vladan are confident that the TelemetryScheduler timers fire very soon after waking up from long sleeps. We are also fine with potentially a few secs of additional data from the data collection view point, so i'm closing this.
Status: NEW → RESOLVED
Closed: 10 years ago
Resolution: --- → WORKSFORME