Closed Bug 1504892 Opened 6 years ago Closed 6 years ago

Sender parameters are not reset after pc.removeTrack(sender)

Categories

(Core :: WebRTC: Signaling, enhancement, P3)

65 Branch
enhancement

Tracking

()

RESOLVED INVALID
Tracking Status
firefox65 --- affected

People

(Reporter: ibc, Unassigned)

Details

As described here:

https://github.com/w3c/webrtc-pc/issues/2025

This is unclear in the spec. However IMHO it would make sense that, once `pc.removeTrack(transceiver.sender)` is called, if later we add a new track via `transceiver.sender.replaceTrack(newTrack)`, previous sender settings (such as simulcast/encodings) should be reset.

However, this is not true in Firefox (previous sender parameters are kept).
Priority: -- → P3
We also need to think through whether send SSRC should change here.
The spec seems clear about what removeTrack should do, and it doesn't involve resetting sender parameters, so I'm closing this issue.
Status: NEW → RESOLVED
Closed: 6 years ago
Resolution: --- → INVALID