Closed Bug 264819 Opened 20 years ago Closed 19 years ago

Flash when focusing link inside scrollable absolute positioned div

Categories

(Core :: Web Painting, defect)

x86
Windows XP
defect
Not set
normal

Tracking

()

RESOLVED WORKSFORME

People

(Reporter: martijn.martijn, Assigned: roc)

References

()

Details

(Keywords: regression, testcase)

Attachments

(2 files, 1 obsolete file)

User-Agent:       Mozilla/5.0 (Windows; U; Windows NT 5.1; en-US; rv:1.8a5) Gecko/20041017 Firefox/0.9.1+
Build Identifier: Mozilla/5.0 (Windows; U; Windows NT 5.1; en-US; rv:1.8a5) Gecko/20041017 Firefox/0.9.1+

1. Focus the scrollable div with all the images
2. Scroll to the bottom of that div
3. Now focus one of the links in that div (using right-click for example)

Result -> you'll see some flash in the recent nightlies.

This seems some kind of regression.
I don't see it happening in:
Mozilla/5.0 (Windows; U; Windows NT 5.1; en-US; rv:1.8a5) Gecko/20041008
Firefox/0.9.1+ (7:12 am)
But I see it happening in:
Mozilla/5.0 (Windows; U; Windows NT 5.1; en-US; rv:1.8a5) Gecko/20041009
Firefox/0.9.1+ (7:33 am)

Bonsai link:
http://bonsai.mozilla.org/cvsquery.cgi?treeid=default&module=all&branch=HEAD&branchtype=match&dir=&file=&filetype=match&who=&whotype=match&sortby=Date&hours=2&date=explicit&mindate=2004-10-08+06%3A00%3A00&maxdate=2004-10-09+08%3A00%3A00&cvsroot=%2Fcvsroot

I'll attach a minimalish testcase.

Reproducible: Always
Steps to Reproduce:
Attached file Testcase (obsolete) —
Follow the steps in the testcase to trigger the bug.
Keywords: regression, testcase
(In reply to comment #1)
> Created an attachment (id=162423)
> Testcase
> 
> Follow the steps in the testcase to trigger the bug.

The test case didn't happen for me.
Mozilla/5.0 (Windows; U; Windows NT 5.1; en-US; rv:1.7.3) Gecko/20041018
Firefox/1.0 (bangbang023)
Oops, just now realizing that was in Mozilla Browser and I'm using Firefox. Sorry.
Worksforme with a gtk1 build.  Is this a Windows widgetry problem?
Attached file testcase
oveflow:auto <div>'s are not automatically focused anymore when clicking on it.

This testcase is the same as the original, but with tabindex="1" which makes
the <div> focused again by clicking on it.
Attachment #162423 - Attachment is obsolete: true
That still worksforme with Linux trunk build 2004-10-24-05.
Attached file testcase2
Another case where I experience this bug. Follow the steps in the testcase to
trigger the bug.
Originally I saw this bug at:
http://www.mozilla.org/start/1.0/demos/eagle-sun.html
Hmm, for some reason I get brief flashes of white now, instead of red with
"testcase2", when I try to trigger the bug.
Sounds like the multiple widgets confuse things could well be similar to bug 47742.
Depends on: 47742
This is WORKSFORME in current trunk build.
The last time is saw this bug is in a 2005-01-03 build, but in a 2005-03-02
build, I don't see the bug anymore.
Status: NEW → RESOLVED
Closed: 19 years ago
Resolution: --- → WORKSFORME
No longer depends on: 47742
Component: Layout: View Rendering → Layout: Web Painting
You need to log in before you can comment on or make changes to this bug.