Disk failure on cm-ixstore01 (can't browse tinderbox-builds and try-builds for Firefox or Fennec)
Categories
(mozilla.org Graveyard :: Server Operations, task)
Tracking
(Not tracked)
RESOLVED
FIXED
People
(Reporter: nthomas, Assigned: rbryce)
References
Details
The following locations are currently inaccessible
http://ftp.mozilla.org/pub/mozilla.org/firefox/tinderbox-builds/old
http://ftp.mozilla.org/pub/mozilla.org/mobile/tinderbox-builds/old
http://ftp.mozilla.org/pub/mozilla.org/firefox/try-builds/old
http://ftp.mozilla.org/pub/mozilla.org/mobile/try-builds/old
due to a disk failure. From a disk space point of view we can survive not moving builds there for a couple of days or so.
Over to rbryce for the technical info.
| Reporter | ||
Comment 1•14 years ago
|
||
Same for all dirs which have some reference to a cm-ixstore share, which is everything given in comment #0 with /old trimmed off (either old itself, or something like mobile/tinderbox-builds/mozilla-central-android/ which has having symlinks back into that).
Direct requests still work, so the tests on the Firefox trees still work and the trees are open.
| Reporter | ||
Updated•14 years ago
|
Summary: Disk failure on cm-ixstore01 → Disk failure on cm-ixstore01 (can't browse tinderbox-builds and try-builds for Firefox or Fennec)
| Assignee | ||
Comment 3•14 years ago
|
||
RAID is recovering at the moment. I'll keep this open until I can confirm a succesful rebuild.
Comment 4•14 years ago
|
||
Did we lose more than one disk? One shouldn't have taken the storage offline, should it?
| Assignee | ||
Comment 5•14 years ago
|
||
Update --
Personalities : [raid10]
md0 : active raid10 sdx1[20](S) sdw1[19] sdv1[18] sdu1[17] sdt1[16] sdr1[14] sdq1[21](S) sdp1[13] sdo1[12] sdm1[10] sdl1[9] sdk1[8] sdj1[7] sdi1[22](S) sdh1[6] sdg1[5] sdf1[4] sde1[3] sdd1[1] sdc1[2] sdb1[0]
14651359360 blocks 64K chunks 2 near-copies [20/18] [UUUUUUUUUUU_UUU_UUUU]
[============>........] resync = 64.9% (9510271680/14651359360) finish=1157.6min speed=74016K/sec
| Assignee | ||
Comment 6•14 years ago
|
||
(In reply to Amy Rich [:arich] [:arr] from comment #4)
> Did we lose more than one disk? One shouldn't have taken the storage
> offline, should it?
Correct, one drive failure shouldn't have caused this. However, it appears that a drive failed while resyncing. I failed that drive manually as the resync was stalled and process was in uninterruptable sleep. As you can see in COmment 5 we are are running 18 of 20 discs. The 2 spares should come on-line when the resync is finished. Leaving 1 spare drive until IX can replace the two failed drives.
| Assignee | ||
Comment 7•14 years ago
|
||
Fixed for now...
/dev/md0:
Version : 0.90
Creation Time : Sat Dec 31 04:49:40 2011
Raid Level : raid10
Array Size : 14651359360 (13972.63 GiB 15002.99 GB)
Used Dev Size : 1465135936 (1397.26 GiB 1500.30 GB)
Raid Devices : 20
Total Devices : 21
Preferred Minor : 0
Persistence : Superblock is persistent
Update Time : Tue Mar 20 00:23:43 2012
State : clean
Active Devices : 20
Working Devices : 21
Failed Devices : 0
Spare Devices : 1
Status: NEW → RESOLVED
Closed: 14 years ago
Resolution: --- → FIXED
| Reporter | ||
Comment 8•14 years ago
|
||
Woo! Thanks Rick.