Closed
Bug 1073057
Opened 11 years ago
Closed 11 years ago
Audio ClearOne not functioning in SFO-Espresso
Categories
(Infrastructure & Operations Graveyard :: AVOps: Conference Rooms, task)
Tracking
(Not tracked)
RESOLVED
FIXED
People
(Reporter: ksalsbury, Assigned: ghuerta)
References
Details
The clearone is not initializing. Tried power-cycling multiple times. Comes up to flashing "Initializing..." but never proceeds beyond that.
| Reporter | ||
Updated•11 years ago
|
Assignee: nobody → aarono
| Reporter | ||
Updated•11 years ago
|
Assignee: aarono → jeroentulp
| Reporter | ||
Comment 1•11 years ago
|
||
Problem has been solved for the moment. Soap initiated a staged reboot of the clearone devices and they successfully initialized. This does happen with some frequency, however, so we are requesting additional diagnostics, etc, to determine the cause.
| Assignee | ||
Comment 2•11 years ago
|
||
Aaron could someone from AVDG take a look at the logs.
Flags: needinfo?(aarono)
Hi Guillermo, we have seen this requires further investigation in SFO-expresso
Thanks
| Reporter | ||
Updated•11 years ago
|
Assignee: jeroentulp → ghuerta
Is this room available tomorrow? I would like to send a tech and see if we can reproduce the issue, thanks
Please advise on who to call to schedule this room, thanks
Flags: needinfo?(ghuerta)
Comment 6•11 years ago
|
||
Hello. Please feel free to contact me or ksalsbury for room scheduling. Room is available all day today and Monday the 6th until 3PM.
Flags: needinfo?(aarono)
| Assignee | ||
Updated•11 years ago
|
Flags: needinfo?(ghuerta)
This room is booked for service Tuesday Oct 7th so we can reproduce the issue
Objectives
1) Figure out why we need to keep rebooting the clear one
2) Test a reboot with no Ethernet NIC plugged in to see if it clears the reboot
Please note we will be updating firmware on this clearone tomorrow to test for resolve of the reboot issue, thanks
Comment 9•11 years ago
|
||
Firmware for the ClearOnce equipment was upgraded by Jason of ADVG this morning. We will monitor for some time before closing bug. Jason recommended that if we have to reboot/power the ClearOnes that we unplug the network cable and not plug back in until the device has powered on completely.
Status: NEW → ASSIGNED
Comment 10•11 years ago
|
||
Date: 10/7/14
Arrival Time: 9:30
Departure Time: 10:30
Contact: Mike Poessey
Site Address: 2 Harrison St, San Francisco, CA 94105
Location(s): SFO-Espresso
Problem(s) reported: DSP Issue
Other Issue(s) found onsite: Updated DSP firmware to the latest and greatest. After installing new firmware the VH20 still had the issue of getting stuck on init. Found that if I pull the network cable out after a rebooting the unit then would power up and would work fine. Clearone said check the host name being too long and make sure DHCP is turned off.
Actions Taken: Updated firmware, let the client know how to pull the cable out on them rebooting the DSP.
Proposed Next Steps: None.
Client to watch and advise.
Comment 11•11 years ago
|
||
Issue seems to be resolved. I have been monitoring this and the issue has not reappeared.
Status: ASSIGNED → RESOLVED
Closed: 11 years ago
Resolution: --- → FIXED
Updated•10 years ago
|
Product: Audio/Visual Infrastructure → Infrastructure & Operations
Updated•6 years ago
|
Product: Infrastructure & Operations → Infrastructure & Operations Graveyard
You need to log in
before you can comment on or make changes to this bug.
Description
•