lhirlimann@node15.peach.metrics.scl3 ~]$ sudo hpacucli controller slot=0 show Smart Array P420i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 00143802518D400 Cache Serial Number: PBKUA0BRH3XFND RAID 6 (ADG) Status: Enabled Controller Status: OK Hardware Revision: B Firmware Version: 6.64 Rebuild Priority: Low Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Automatic Monitor and Performance Delay: 60 min Elevator Sort: Enabled Degraded Performance Optimization: Disabled Inconsistency Repair Policy: Disabled Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 15 secs Cache Board Present: True Cache Status: Permanently Disabled Cache Status Details: Cache disabled; battery/capacitor failed to charge to an acceptable level Cache Ratio: 25% Read / 75% Write Drive Write Cache: Disabled Total Cache Size: 512 MB Total Cache Memory Available: 304 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Capacitors Battery/Capacitor Count: 1 | Battery/Capacitor Status: Failed (Replace Batteries) SATA NCQ Supported: True Spare Activation Mode: Activate on physical drive failure (default) Controller Temperature (C): 70 Cache Module Temperature (C): 43 Capacitor Temperature (C): 32 Number of Ports: 2 Internal only Encryption Supported: False Driver Name: hpsa Driver Version: 3.4.4 Driver Supports HP SSD Smart Path: True
Case ID is 4652421473
colo-trip: --- → scl3
Whiteboard: Case ID is 4652421473
Battery replacement came in. Can someone take node15.peach.metrics out of rotation?
Flags: needinfo?(botsas)
Flags: needinfo?(bahena)
node15.peach has been pulled out of the cluster. Please proceed with the maintenance.
Flags: needinfo?(botsas)
Battery replaced. :botsas - can you add the node back to the cluster? [vhua@node15.peach.metrics.scl3 ~]$ sudo hpacucli controller slot=0 show Smart Array P420i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 00143802518D400 Cache Serial Number: PBKUA0BRH3XFND RAID 6 (ADG) Status: Enabled Controller Status: OK Hardware Revision: B Firmware Version: 6.64 Rebuild Priority: Low Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Automatic Monitor and Performance Delay: 60 min Elevator Sort: Enabled Degraded Performance Optimization: Disabled Inconsistency Repair Policy: Disabled Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 15 secs Cache Board Present: True Cache Status: OK Cache Ratio: 25% Read / 75% Write Drive Write Cache: Disabled Total Cache Size: 512 MB Total Cache Memory Available: 304 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Capacitors Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Spare Activation Mode: Activate on physical drive failure (default) Controller Temperature (C): 59 Cache Module Temperature (C): 40 Capacitor Temperature (C): 33 Number of Ports: 2 Internal only Encryption Supported: False Driver Name: hpsa Driver Version: 3.4.4 Driver Supports HP SSD Smart Path: True
Flags: needinfo?(botsas)
node15.peach has been added back to the cluster.
Flags: needinfo?(botsas)