Closed
Bug 1206367
Opened 11 years ago
Closed 11 years ago
Please replace battery on controller 0 node15.peach.metrics.scl3.mozilla.com
Categories
(Infrastructure & Operations :: DCOps, task)
Infrastructure & Operations
DCOps
Tracking
(Not tracked)
RESOLVED
FIXED
People
(Reporter: Usul, Unassigned)
Details
(Whiteboard: Case ID is 4652421473)
lhirlimann@node15.peach.metrics.scl3 ~]$ sudo hpacucli controller slot=0 show
Smart Array P420i in Slot 0 (Embedded)
Bus Interface: PCI
Slot: 0
Serial Number: 00143802518D400
Cache Serial Number: PBKUA0BRH3XFND
RAID 6 (ADG) Status: Enabled
Controller Status: OK
Hardware Revision: B
Firmware Version: 6.64
Rebuild Priority: Low
Expand Priority: Medium
Surface Scan Delay: 3 secs
Surface Scan Mode: Idle
Queue Depth: Automatic
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 15 secs
Cache Board Present: True
Cache Status: Permanently Disabled
Cache Status Details: Cache disabled; battery/capacitor failed to charge to an acceptable level
Cache Ratio: 25% Read / 75% Write
Drive Write Cache: Disabled
Total Cache Size: 512 MB
Total Cache Memory Available: 304 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Capacitors
Battery/Capacitor Count: 1
| Battery/Capacitor Status: Failed (Replace Batteries)
SATA NCQ Supported: True
Spare Activation Mode: Activate on physical drive failure (default)
Controller Temperature (C): 70
Cache Module Temperature (C): 43
Capacitor Temperature (C): 32
Number of Ports: 2 Internal only
Encryption Supported: False
Driver Name: hpsa
Driver Version: 3.4.4
Driver Supports HP SSD Smart Path: True
Comment 1•11 years ago
|
||
Case ID is 4652421473
colo-trip: --- → scl3
Whiteboard: Case ID is 4652421473
Comment 2•11 years ago
|
||
Battery replacement came in. Can someone take node15.peach.metrics out of rotation?
Flags: needinfo?(botsas)
Flags: needinfo?(bahena)
Comment 3•11 years ago
|
||
node15.peach has been pulled out of the cluster. Please proceed with the maintenance.
Flags: needinfo?(botsas)
Comment 4•11 years ago
|
||
Battery replaced. :botsas - can you add the node back to the cluster?
[vhua@node15.peach.metrics.scl3 ~]$ sudo hpacucli controller slot=0 show
Smart Array P420i in Slot 0 (Embedded)
Bus Interface: PCI
Slot: 0
Serial Number: 00143802518D400
Cache Serial Number: PBKUA0BRH3XFND
RAID 6 (ADG) Status: Enabled
Controller Status: OK
Hardware Revision: B
Firmware Version: 6.64
Rebuild Priority: Low
Expand Priority: Medium
Surface Scan Delay: 3 secs
Surface Scan Mode: Idle
Queue Depth: Automatic
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 15 secs
Cache Board Present: True
Cache Status: OK
Cache Ratio: 25% Read / 75% Write
Drive Write Cache: Disabled
Total Cache Size: 512 MB
Total Cache Memory Available: 304 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Capacitors
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
Spare Activation Mode: Activate on physical drive failure (default)
Controller Temperature (C): 59
Cache Module Temperature (C): 40
Capacitor Temperature (C): 33
Number of Ports: 2 Internal only
Encryption Supported: False
Driver Name: hpsa
Driver Version: 3.4.4
Driver Supports HP SSD Smart Path: True
Flags: needinfo?(botsas)
| Reporter | ||
Updated•11 years ago
|
Status: NEW → RESOLVED
Closed: 11 years ago
Resolution: --- → FIXED
Updated•8 years ago
|
Flags: needinfo?(bahena)
QA Contact: cshields
You need to log in
before you can comment on or make changes to this bug.