Closed Bug 1518729 Opened 7 years ago Closed 7 years ago

[MDC2] remote-hands work for network failures on moonshot 11/14

Categories

(Infrastructure & Operations :: RelOps: Hardware, task)

task
Not set
normal

Tracking

(Not tracked)

RESOLVED FIXED

People

(Reporter: arny, Assigned: dhouse)

References

Details

Please ask QTS to reseat this cartridges. More detail in 1512426.

T-w1064-ms-465 Chassis 11 cartridge 30
T-W1064-MS-474 Chassis 11 cartridge 39
T-W1064-MS-599 Chassis 14 cartridge 29

I'll create a ticket for QTS to re-seat these 3 cartridges in MDC2.

Assignee: nobody → dhouse

I opened REQ0263557 to ask QTS to re-seat the cartridges:

host	Rack	Shelf	Cartridge	Asset#
465	GC136	16	30	34411
474	GC136	16	39	34420
599	GC135	11	29	34545

Please re-seat these three moonshot cartridges (Power-off the cartridge, remove it from the slot, re-insert it into the slot, power it back on).

If you have any concerns or problems, please phone me. Thanks!

-David

QTS reseated the three cartridges.

Status: NEW → RESOLVED
Closed: 7 years ago
Resolution: --- → FIXED
Status: RESOLVED → REOPENED
Resolution: FIXED → ---
Summary: Reseat cartridges → [MDC2] remote-hands work for network failures on moonshot 11/14

The machines still do not pass PXE boot. So, let's try swapping them to other slots to see if it is not a problem specific to the cartridge and config(network for this mac).

plan:

current:
host Rack Shelf Cartridge Asset#
465 GC136 16 30 34411
474 GC136 16 39 34420
599 GC135 11 29 34545

swap with for testing (swap each down one cartridge slot number and asset#):
host Rack Shelf Cartridge Asset#
464 GC136 16 29 34410
473 GC136 16 38 34419
598 GC135 11 28 34544

No current bugs for these three targets.
All three show they have been completing tasks on taskcluster:
https://tools.taskcluster.net/provisioners/releng-hardware/worker-types/gecko-t-win10-64-hw/workers/mdc2/T-W1064-MS-464
https://tools.taskcluster.net/provisioners/releng-hardware/worker-types/gecko-t-win10-64-hw/workers/mdc2/T-W1064-MS-473
https://tools.taskcluster.net/provisioners/releng-hardware/worker-types/gecko-t-win10-64-hw/workers/mdc2/T-W1064-MS-598
The queue for gecko-t-win10-64-hw is at zero. So I think it is okay to remove 3 workers for testing.

I'll ask QTS to swap with these cartridges.

I quarantined(taskcluster) and acpi shut down all 3 target cartridges:
T-w1064-ms-464 Chassis 11 cartridge 29
T-W1064-MS-473 Chassis 11 cartridge 38
T-W1064-MS-598 Chassis 14 cartridge 28

I also powered-down the problem cartridges:
T-w1064-ms-465 Chassis 11 cartridge 30
T-W1064-MS-474 Chassis 11 cartridge 39
T-W1064-MS-599 Chassis 14 cartridge 29

All are marked with their UID's on.

I submitted the QTS remote-hands request to perform the swap and contact me: RITM0279872

599 (in place of 598) pxe boots correctly to a windows deployment prompt. I initiated the deployment process on it as a dc worker.
598 in 599's place: pxe boot fails. correctly boots local disk, but has some network connection failures (strangely, it can push log messages to the log-aggregators but reports a problem with that:

Jan 14 10:39:56 T-W1064-MS-598.mdc2.mozilla.com nxlog: ERROR couldn't connect to tcp socket on log-aggregator.srv.releng.mdc2.mozilla.com:514; A connection attempt failed because the connected party did not properly respond after a period of time, or established connection failed because connected host has failed to respond.  #015 

I powered 598 down. I'll power down 599 when imaging completes, and then I'll have QTS swap them back to their original positions.

465 in 464's place does not pxe boot
464 in 465's place does not pxe boot

474 in 473's place pxe boots correctly to windows deployment. I initiated the deployment as a dc worker.
473 in 474's place does not pxe boot

the deployment completed on both 599 and 474.
I've asked QTS to swap all 6 back to their original places.

I un-quarantined the swap/test workers.

QTS swapped them back around 1:00 pacific and powered them on.
I see they've taken tasks in taskcluster since then.

I've asked Van in bug 1496230 if he can check the network config or knows if there is something else that could cause the difference in network connectivity between the cartridge slots.

Status: REOPENED → RESOLVED
Closed: 7 years ago → 7 years ago
Resolution: --- → FIXED