please reimage 66 pandas (6 chassis) with raw android image
Categories
(Infrastructure & Operations :: DCOps, task)
Tracking
(Not tracked)
RESOLVED
FIXED
People
(Reporter: jmaher, Unassigned)
References
Details
We need to get testing and the next step is to get this latest/final image of android on some panda boards. This is not using lifeguard, but the old fashioned method of a raw flash of the .img file.
The image is located here:
http://people.mozilla.org/~jmaher/panda/panda_2gb_v2.img.bz2
I have validated this in a series of pandas in chassis 2.
Comment 1•12 years ago
|
||
:jmaher, is there any specific 6 chassis we should install this new image in?
Comment 2•12 years ago
|
||
Also, we can arrange to manually image 6 chassis for a special case like this, but it's simply not sustainable in the long term. I'm comfortable with this request, as long as it isn't the final production solution.
Reporter | ||
Comment 3•12 years ago
|
||
no specific ones that I know of. We should avoid chassis 2 and 3. I am not sure what other chassis are used for b2g and cedar android testing. My take is use whatever 6 are the most accessible.
:kmoir or :dividehex, any other information we should consider?
Reporter | ||
Comment 4•12 years ago
|
||
this is the same solution we have used for the tegras over the last 3 years. We are working on a solution similar to what we are doing for b2g, it isn't ready. For the near future I see us doing a lot of hand flashing while we ramp up the panda android testing and sometime next quarter we will have a lifeguard based solution for android.
Comment 5•12 years ago
|
||
(In reply to Joel Maher (:jmaher) from comment #3)
> no specific ones that I know of. We should avoid chassis 2 and 3. I am not
> sure what other chassis are used for b2g and cedar android testing. My take
> is use whatever 6 are the most accessible.
>
> :kmoir or :dividehex, any other information we should consider?
My opinion is we should make sure that at *least* half are not-in-same-rack/vlan. Such that if a single switch goes down we don't lose the whole pool.
:arr since I know there are still some issues with individual relay boards, and that you're also not done configuring relay boards, are there specific chasis's you can recommend?
Comment 6•12 years ago
|
||
Regarding comment 3, here is the current state
chassis 2 (panda-{0022..0033}): releng staging + joel
chassis 3 (panda-{0034..0045}): relops
chassis 4 (panda-{0046..0057}): kmoir (cedar tests in prod)
chassis 5 (panda-{0058..0069}): kmoir (cedar tests in prod)
Chassis-0[07-14] and panda-00[82-169] b2g android
Updated•12 years ago
|
colo-trip: --- → scl1
Comment 7•12 years ago
|
||
The image has been deployed to Pandas-[0808-0873] which are panda-chassis-[073-078].
Updated•12 years ago
|
Status: NEW → RESOLVED
Closed: 12 years ago
Resolution: --- → FIXED
Comment 8•12 years ago
|
||
Note that you *MUST* set the state of pandas to locked_out when you hard code an image on them. Otherwise mozpool will still happily try to control them and reboot them and attempt to reimage them at will. I have set panda-{0808..0873} in the locked out state and added a comment about this bug for now.
Reporter | ||
Comment 9•12 years ago
|
||
Are these using the hardcoded image file (i.e. dd if=android.img of=/dev/sdb) instead of the preseed image which we use for b2g and lifeguard?
Comment 10•12 years ago
|
||
these are using the image you linked in comment 1.
>The image is located here:
>http://people.mozilla.org/~jmaher/panda/panda_2gb_v2.img.bz2
Van
Updated•10 years ago
|
Product: mozilla.org → Infrastructure & Operations
You need to log in
before you can comment on or make changes to this bug.
Description
•