Closed Bug 820825 Opened 12 years ago Closed 12 years ago

please reimage 66 pandas (6 chassis) with raw android image

Categories

(Infrastructure & Operations :: DCOps, task)

ARM
Android
task
Not set
normal

Tracking

(Not tracked)

RESOLVED FIXED

People

(Reporter: jmaher, Unassigned)

References

Details

We need to get testing and the next step is to get this latest/final image of android on some panda boards. This is not using lifeguard, but the old fashioned method of a raw flash of the .img file. The image is located here: http://people.mozilla.org/~jmaher/panda/panda_2gb_v2.img.bz2 I have validated this in a series of pandas in chassis 2.
:jmaher, is there any specific 6 chassis we should install this new image in?
Also, we can arrange to manually image 6 chassis for a special case like this, but it's simply not sustainable in the long term. I'm comfortable with this request, as long as it isn't the final production solution.
no specific ones that I know of. We should avoid chassis 2 and 3. I am not sure what other chassis are used for b2g and cedar android testing. My take is use whatever 6 are the most accessible. :kmoir or :dividehex, any other information we should consider?
this is the same solution we have used for the tegras over the last 3 years. We are working on a solution similar to what we are doing for b2g, it isn't ready. For the near future I see us doing a lot of hand flashing while we ramp up the panda android testing and sometime next quarter we will have a lifeguard based solution for android.
(In reply to Joel Maher (:jmaher) from comment #3) > no specific ones that I know of. We should avoid chassis 2 and 3. I am not > sure what other chassis are used for b2g and cedar android testing. My take > is use whatever 6 are the most accessible. > > :kmoir or :dividehex, any other information we should consider? My opinion is we should make sure that at *least* half are not-in-same-rack/vlan. Such that if a single switch goes down we don't lose the whole pool. :arr since I know there are still some issues with individual relay boards, and that you're also not done configuring relay boards, are there specific chasis's you can recommend?
Regarding comment 3, here is the current state chassis 2 (panda-{0022..0033}): releng staging + joel chassis 3 (panda-{0034..0045}): relops chassis 4 (panda-{0046..0057}): kmoir (cedar tests in prod) chassis 5 (panda-{0058..0069}): kmoir (cedar tests in prod) Chassis-0[07-14] and panda-00[82-169] b2g android
colo-trip: --- → scl1
The image has been deployed to Pandas-[0808-0873] which are panda-chassis-[073-078].
Status: NEW → RESOLVED
Closed: 12 years ago
Resolution: --- → FIXED
Note that you *MUST* set the state of pandas to locked_out when you hard code an image on them. Otherwise mozpool will still happily try to control them and reboot them and attempt to reimage them at will. I have set panda-{0808..0873} in the locked out state and added a comment about this bug for now.
Are these using the hardcoded image file (i.e. dd if=android.img of=/dev/sdb) instead of the preseed image which we use for b2g and lifeguard?
these are using the image you linked in comment 1. >The image is located here: >http://people.mozilla.org/~jmaher/panda/panda_2gb_v2.img.bz2 Van
Product: mozilla.org → Infrastructure & Operations