Sal had a look at both today, but didn't get them fixed in the time available.
stone-ridge-panda-05 has no link light, but has link. Its log shows it restarting without being told to, as it tries to download and extract Android repeatedly:
2012-12-28T15:04:04 statemachine entering state pxe_power_cycling
2012-12-28T15:04:04 bmm setting PXE config to 'panda-android.2'
2012-12-28T15:04:04 bmm initiating power cycle
2012-12-28T15:04:07 statemachine entering state pxe_booting
2012-12-28T15:04:29 bmm clearing PXE config
2012-12-28T15:04:29 statemachine entering state android_downloading
2012-12-28T15:04:48 statemachine entering state android_extracting
2012-12-28T15:06:18 statemachine ignored event android_downloading in state android_extracting
2012-12-28T15:06:36 statemachine ignored event android_extracting in state android_extracting
2012-12-28T15:09:29 statemachine ignored event android_downloading in state android_extracting
2012-12-28T15:09:47 statemachine ignored event android_extracting in state android_extracting
2012-12-28T15:12:38 statemachine ignored event android_downloading in state android_extracting
2012-12-28T15:12:57 statemachine ignored event android_extracting in state android_extracting
2012-12-28T15:14:55 statemachine entering state pxe_power_cycling
2012-12-28T15:14:55 bmm setting PXE config to 'panda-android.2'
2012-12-28T15:14:55 bmm initiating power cycle
2012-12-28T15:14:58 statemachine entering state pxe_booting
-10 seems to just not be there - perhaps a power problem?
2012-12-28T15:11:15 statemachine entering state pxe_power_cycling
2012-12-28T15:11:15 bmm setting PXE config to 'panda-android.2'
2012-12-28T15:11:15 bmm initiating power cycle
2012-12-28T15:11:18 statemachine entering state pxe_booting
2012-12-28T15:14:25 statemachine entering state pxe_power_cycling
2012-12-28T15:14:25 bmm setting PXE config to 'panda-android.2'
2012-12-28T15:14:25 bmm initiating power cycle
2012-12-28T15:14:28 statemachine entering state pxe_booting
Comment 1•13 years ago
|
||
This was my fault, these 2 pandas had identical MAC addresses. I have fixed this issue in inventory however another came up. The relay board's ethernet module died in this chassis and we're in the process of procuring spares.
Van
Updated•13 years ago
|
colo-trip: --- → scl3
Comment 2•13 years ago
|
||
Replaced the relay board's ethernet module and updated the mac address
| Reporter | ||
Comment 3•13 years ago
|
||
I'm still seeing this time out when trying to contact the relay server:
socket(PF_INET, SOCK_STREAM, IPPROTO_IP) = 3
fcntl(3, F_GETFL) = 0x2 (flags O_RDWR)
fcntl(3, F_SETFL, O_RDWR|O_NONBLOCK) = 0
connect(3, {sa_family=AF_INET, sin_port=htons(2101), sin_addr=inet_addr("10.22.92.128")}, 16) = -1 EINPROGRESS (Operation now in progress)
select(4, [], [3], [3], {59, 999995}) = 1 (out [3], left {59, 997192})
getsockopt(3, SOL_SOCKET, SO_ERROR, [0], [4]) = 0
getsockopt(3, SOL_SOCKET, SO_ERROR, [0], [4]) = 0
# START_COMMAND
sendto(3, "\376", 1, 0, NULL, 0) = 1
select(4, [], [3], [3], {59, 996791}) = 1 (out [3], left {59, 996790})
# READ_RELAY_N_AT_BANK(6)
sendto(3, "y", 1, 0, NULL, 0) = 1
select(4, [], [3], [3], {59, 996698}) = 1 (out [3], left {59, 996697})
# bank 2
sendto(3, "\2", 1, 0, NULL, 0) = 1
select(4, [3], [], [3], {59, 996612}
.... crickets ....
So it looks like the ethernet module is working OK (its web interface is fine too). Is this a bad relay module?
Comment 4•13 years ago
|
||
I am not sure. DCOPS has never installed any of the relay modules either.
:dividehex, is this something you can answer?
Comment 5•13 years ago
|
||
(In reply to Dustin J. Mitchell [:dustin] from comment #3)
> I'm still seeing this time out when trying to contact the relay server:
>
> socket(PF_INET, SOCK_STREAM, IPPROTO_IP) = 3
> fcntl(3, F_GETFL) = 0x2 (flags O_RDWR)
> fcntl(3, F_SETFL, O_RDWR|O_NONBLOCK) = 0
> connect(3, {sa_family=AF_INET, sin_port=htons(2101),
> sin_addr=inet_addr("10.22.92.128")}, 16) = -1 EINPROGRESS (Operation now in
> progress)
> select(4, [], [3], [3], {59, 999995}) = 1 (out [3], left {59, 997192})
> getsockopt(3, SOL_SOCKET, SO_ERROR, [0], [4]) = 0
> getsockopt(3, SOL_SOCKET, SO_ERROR, [0], [4]) = 0
> # START_COMMAND
> sendto(3, "\376", 1, 0, NULL, 0) = 1
> select(4, [], [3], [3], {59, 996791}) = 1 (out [3], left {59, 996790})
> # READ_RELAY_N_AT_BANK(6)
> sendto(3, "y", 1, 0, NULL, 0) = 1
> select(4, [], [3], [3], {59, 996698}) = 1 (out [3], left {59, 996697})
> # bank 2
> sendto(3, "\2", 1, 0, NULL, 0) = 1
> select(4, [3], [], [3], {59, 996612}
> .... crickets ....
>
> So it looks like the ethernet module is working OK (its web interface is
> fine too). Is this a bad relay module?
The default baud rate of 9600 needs to be changed to 112500 and doesn't work out of the box. I reconfigured it per the mana instructions so it should work now.
Comment 6•13 years ago
|
||
:dustin, are we ok with these 2 pandas now?
| Reporter | ||
Comment 7•13 years ago
|
||
Yep, thanks!
Status: NEW → RESOLVED
Closed: 13 years ago
Resolution: --- → FIXED
Updated•11 years ago
|
Product: mozilla.org → Infrastructure & Operations
You need to log in
before you can comment on or make changes to this bug.
Description
•