Closed Bug 825339 Opened 13 years ago Closed 13 years ago

stone-ridge-panda-{05,10} misbehaving

Categories

(Infrastructure & Operations :: DCOps, task)

task
Not set
normal

Tracking

(Not tracked)

RESOLVED FIXED

People

(Reporter: dustin, Unassigned)

References

Details

Sal had a look at both today, but didn't get them fixed in the time available. stone-ridge-panda-05 has no link light, but has link. Its log shows it restarting without being told to, as it tries to download and extract Android repeatedly: 2012-12-28T15:04:04 statemachine entering state pxe_power_cycling 2012-12-28T15:04:04 bmm setting PXE config to 'panda-android.2' 2012-12-28T15:04:04 bmm initiating power cycle 2012-12-28T15:04:07 statemachine entering state pxe_booting 2012-12-28T15:04:29 bmm clearing PXE config 2012-12-28T15:04:29 statemachine entering state android_downloading 2012-12-28T15:04:48 statemachine entering state android_extracting 2012-12-28T15:06:18 statemachine ignored event android_downloading in state android_extracting 2012-12-28T15:06:36 statemachine ignored event android_extracting in state android_extracting 2012-12-28T15:09:29 statemachine ignored event android_downloading in state android_extracting 2012-12-28T15:09:47 statemachine ignored event android_extracting in state android_extracting 2012-12-28T15:12:38 statemachine ignored event android_downloading in state android_extracting 2012-12-28T15:12:57 statemachine ignored event android_extracting in state android_extracting 2012-12-28T15:14:55 statemachine entering state pxe_power_cycling 2012-12-28T15:14:55 bmm setting PXE config to 'panda-android.2' 2012-12-28T15:14:55 bmm initiating power cycle 2012-12-28T15:14:58 statemachine entering state pxe_booting -10 seems to just not be there - perhaps a power problem? 2012-12-28T15:11:15 statemachine entering state pxe_power_cycling 2012-12-28T15:11:15 bmm setting PXE config to 'panda-android.2' 2012-12-28T15:11:15 bmm initiating power cycle 2012-12-28T15:11:18 statemachine entering state pxe_booting 2012-12-28T15:14:25 statemachine entering state pxe_power_cycling 2012-12-28T15:14:25 bmm setting PXE config to 'panda-android.2' 2012-12-28T15:14:25 bmm initiating power cycle 2012-12-28T15:14:28 statemachine entering state pxe_booting
Depends on: 825690
This was my fault, these 2 pandas had identical MAC addresses. I have fixed this issue in inventory however another came up. The relay board's ethernet module died in this chassis and we're in the process of procuring spares. Van
colo-trip: --- → scl3
Replaced the relay board's ethernet module and updated the mac address
I'm still seeing this time out when trying to contact the relay server: socket(PF_INET, SOCK_STREAM, IPPROTO_IP) = 3 fcntl(3, F_GETFL) = 0x2 (flags O_RDWR) fcntl(3, F_SETFL, O_RDWR|O_NONBLOCK) = 0 connect(3, {sa_family=AF_INET, sin_port=htons(2101), sin_addr=inet_addr("10.22.92.128")}, 16) = -1 EINPROGRESS (Operation now in progress) select(4, [], [3], [3], {59, 999995}) = 1 (out [3], left {59, 997192}) getsockopt(3, SOL_SOCKET, SO_ERROR, [0], [4]) = 0 getsockopt(3, SOL_SOCKET, SO_ERROR, [0], [4]) = 0 # START_COMMAND sendto(3, "\376", 1, 0, NULL, 0) = 1 select(4, [], [3], [3], {59, 996791}) = 1 (out [3], left {59, 996790}) # READ_RELAY_N_AT_BANK(6) sendto(3, "y", 1, 0, NULL, 0) = 1 select(4, [], [3], [3], {59, 996698}) = 1 (out [3], left {59, 996697}) # bank 2 sendto(3, "\2", 1, 0, NULL, 0) = 1 select(4, [3], [], [3], {59, 996612} .... crickets .... So it looks like the ethernet module is working OK (its web interface is fine too). Is this a bad relay module?
I am not sure. DCOPS has never installed any of the relay modules either. :dividehex, is this something you can answer?
(In reply to Dustin J. Mitchell [:dustin] from comment #3) > I'm still seeing this time out when trying to contact the relay server: > > socket(PF_INET, SOCK_STREAM, IPPROTO_IP) = 3 > fcntl(3, F_GETFL) = 0x2 (flags O_RDWR) > fcntl(3, F_SETFL, O_RDWR|O_NONBLOCK) = 0 > connect(3, {sa_family=AF_INET, sin_port=htons(2101), > sin_addr=inet_addr("10.22.92.128")}, 16) = -1 EINPROGRESS (Operation now in > progress) > select(4, [], [3], [3], {59, 999995}) = 1 (out [3], left {59, 997192}) > getsockopt(3, SOL_SOCKET, SO_ERROR, [0], [4]) = 0 > getsockopt(3, SOL_SOCKET, SO_ERROR, [0], [4]) = 0 > # START_COMMAND > sendto(3, "\376", 1, 0, NULL, 0) = 1 > select(4, [], [3], [3], {59, 996791}) = 1 (out [3], left {59, 996790}) > # READ_RELAY_N_AT_BANK(6) > sendto(3, "y", 1, 0, NULL, 0) = 1 > select(4, [], [3], [3], {59, 996698}) = 1 (out [3], left {59, 996697}) > # bank 2 > sendto(3, "\2", 1, 0, NULL, 0) = 1 > select(4, [3], [], [3], {59, 996612} > .... crickets .... > > So it looks like the ethernet module is working OK (its web interface is > fine too). Is this a bad relay module? The default baud rate of 9600 needs to be changed to 112500 and doesn't work out of the box. I reconfigured it per the mana instructions so it should work now.
:dustin, are we ok with these 2 pandas now?
Yep, thanks!
Status: NEW → RESOLVED
Closed: 13 years ago
Resolution: --- → FIXED
Product: mozilla.org → Infrastructure & Operations
You need to log in before you can comment on or make changes to this bug.